Originally Adopted
September 13, 1983
Revisions herein effective April 15, 1999
I.
Definitions and
Scope
II. Standards of Practice
Mandatory Sections:
-
Foundations, Basements, and Under-floor Areas
-
Exteriors
-
Roof Coverings
-
Attic Areas and Roof Framing
-
Plumbing
-
Electrical Systems
-
Heating Systems
-
Central Cooling Systems
-
Fireplaces and Chimneys
-
Building Interior
Optional Sections:
-
Other Built-in Appliances and Systems
-
Pools and Spas
III.
Limitations, Exceptions and Exclusions
I.
Definitions and Scope
-
Real Estate inspection is a non-invasive
physical examination, performed for a fee,
designed to identify material defects in the
systems, structures, and components of a
building as they exist at the time of the
inspection. The specific systems, structures and
components of a building to be examined are
listed in these Standards of Practice.
-
A
material defect is a condition that
significantly affects the value, desirability,
habitability, or safety of the building. Style
or aesthetics shall not be considered in
determining whether a specific system,
structure, or component is defective.
-
These Standards provide inspection guidelines,
make public the services provided by private
fee-paid inspectors, and define certain terms
relating to these inspections.
-
Sections 1 through 10 of these Standards are a
mandatory part of all such inspections. Sections
11 through 12 are optional.
-
Unless otherwise agreed between the inspector
and client, these Standards shall apply to the
primary building and its associated primary
parking structure. The inspection shall be
limited to those specific systems, structures
and components that are present and visually
accessible. Components and systems shall be
operated with normal user controls only and as
conditions permit. Inspections performed in
accordance with these Standards are not intended
to be technically exhaustive.
-
Inspection reports shall describe and identify
in written format the inspected systems,
structures, and components of the building and
shall identify material defects.
-
Inspection reports may contain recommendations
regarding conditions reported or recommendations
for further evaluation by appropriate persons.
II. Standards of Practice
SECTION 1
- Foundations, Basements, and Under-floor Areas
Top
A.
Items to be identified and reported:
-
Foundation and other support components.
-
Under-floor ventilation.
-
Location of under-floor access opening(s).
-
Wood separation from soil.
-
Presence of drainage systems or sump pumps
within foundation footprint.
-
Presence or absence of seismic anchoring and
bracing components.
B. The inspector is not required to:
-
Enter under-floor areas that are not
accessible or where entry could cause damage or
pose a hazard to the inspector.
-
Move stored items, vegetation or debris, or
perform any excavations or other intrusive
testing to gain access.
-
Operate or evaluate adequacy of sump pumps or
drainage systems.
-
Identify size, spacing, location or adequacy
of foundation bolting and bracing components or
reinforcement systems.
-
Perform any intrusive examination or testing,
or use any special equipment such as, but not
limited to, levels, probes or meters.
SECTION 2
- Exteriors
Top
A.
Items to be identified and reported:
-
Surface grade, hardscaping and drainage within
six feet of the inspected building or associated
primary parking structure.
-
Wall cladding, veneers, flashing, trim, eaves,
soffits and fascias.
-
Exterior portions of a representative sampling
of doors and windows.
-
Attached decks, porches, balconies, stairs,
columns, walkways, guard-rails and handrails.
B. The
inspector is not required to:
-
Operate or evaluate any mechanical,
electro-mechanical, or underground drainage
systems.
-
Operate or evaluate storm windows, storm doors,
screening, shutters or awnings.
-
Operate or evaluate remote-control devices.
-
Examine detached buildings and structures (other
than the primary parking structure), patio
enclosures, fences, and retaining walls.
-
Examine items not visible from a readily
accessible walking surface.
SECTION 3 - Roof Coverings
Top
A. Items to be
identified and reported:
- Roof
coverings.
- Flashing,
vents, skylights and other penetrations.
- Roof drainage
systems.
B. The inspector is
not required to:
- Walk on the
roof surface if, in the opinion of the
inspector, there is a possibility of damage to
the surface or a hazard to the inspector.
- Perform a
water test, warrant or certify against roof
leakage or predict life expectancy.
SECTION 4 - Attic Areas
and Roof Framing
Top
A. Items to be
identified and reported:
- Framing and
sheathing.
- Access
opening(s) and accessibility.
- Insulation
material(s).
- Ventilation.
B. The inspector is
not required to:
- Enter attic
areas that, in the opinion of the inspector, are
not accessible or where entry could cause
damage.
- Remove
insulation materials or identify composition or
"R" value of insulation material.
- Activate
thermostatically operated fans.
SECTION 5 - Plumbing
Top
A. Items to be
identified and reported:
- Supply, waste,
and vent piping.
- Fixtures,
faucets and drains.
- Water heating
equipment, including combustion air, venting,
connections, energy sources, seismic bracing,
and temperature-pressure relief valves.
- Functional
flow of water supply and functional drainage at
fixtures.
- Gas piping and
connectors.
-
Cross-connections.
B. The inspector is
not required to:
- Operate any
valve other than fixture faucets and hose
faucets attached to the building.
- Operate any
system, fixture or component which is shut down
or disconnected.
- Examine or
verify operation of water supply or pressure
assistance systems, including, but not limited
to: wells, pumps, tanks, and related equipment.
- Verify
functional flow or pressure at any fixture or
faucet where the flow end is capped or connected
to an appliance, or measure pressure, volume or
temperature.
- Examine or
operate any sewage disposal system or component
including, but not limited to: septic tanks
and/or any underground system or portion
thereof, or ejector pumps for rain or waste.
- Examine the
overflow device of any fixture.
- Evaluate the
potability of water, compliance with local or
state conservation or energy standards, or
proper design or sizing of any water, waste, and
venting components, fixtures, or piping.
- Identify
whether water supply and waste disposal systems
are public or private.
- Evaluate time
to obtain hot water at fixtures, or perform
testing of any kind to water heater elements.
- Examine
ancillary systems or components such as, but not
limited to: those relating to solar water
heating, hot water circulation, yard sprinklers,
water conditioning, swimming pools or spas and
related equipment, and fire sprinklers.
- Test shower
pans for leakage or fill any fixture with water
during examination.
- Evaluate the
gas supply system for leaks or pressure.
- Determine
effectiveness of anti-siphon, back-flow
prevention, or drain-stop devices.
- Determine
whether there are sufficient clean-outs for
effective clearing of drains.
- Evaluate gas,
liquid propane, or oil storage tanks.
SECTION 6 - Electrical
Systems
Top
A. Items to be
identified and reported:
- Service
conductors, equipment, and capacity.
- Panels and
overcurrent protection devices.
- Service and
equipment grounding.
- Wiring types
and methods.
- A
representative sampling of switches,
receptacles, and light fixtures.
- Ground-fault
circuit-interrupters.
B. The inspector is
not required to:
- Operate
electrical systems or components which are
disconnected or shut down.
- Disconnect any
energized system or appliance.
- Remove
deadfront covers where not accessible, or if
removal could cause injury or damage to persons
or property, or remove device cover plates.
- Operate
overcurrent protection devices, or evaluate
compatibility of overcurrent protection devices
with the panelboard manufacturer.
- Examine or
test smoke detectors.
- Operate
ground-fault circuit-interrupter devices by
other than the manufacturer’s test button.
- Examine
de-icing equipment, or private or emergency
electrical supply sources, including but not
limited to: generators, windmills, photovoltaic
solar collectors, or battery or electrical
storage facilities.
SECTION 7 - Heating
Systems
Top
A. Items to be
identified and reported:
- Heating
equipment and operation using normal user
controls.
- Venting
systems.
- Combustion and
ventilating air.
- Energy source
and connections.
- Heating
distribution system(s) including a
representative sampling of ducting, duct
insulation, outlets, radiators, piping systems
and valves.
B. The inspector is
not required to:
- Examine or
evaluate condition of heat exchangers.
- Determine
uniformity, temperature, airflow or balance of
heat supply to any room or building, or examine
for warming at any heating system distribution
component when access would require steps or a
ladder, or determine leakage in any ductwork.
- Examine
electric heater elements or heat pump fluid/gas
materials, or examine below ground/slab systems,
ducts, fuel tanks and related components.
- Determine or
examine thermostat calibration, heat
anticipation, or automatic setbacks or clocks.
- Examine
radiant or geothermal heat pump systems.
- Examine any
solar-energy heating systems or components.
- Examine
electronic air filtering systems.
- Operate heat
pump systems when the ambient air temperature
may damage the equipment, or operate any heat
pump system in "emergency" heat mode.
- Examine
humidity control systems and components.
SECTION 8 - Central
Cooling Systems
Top
A. Items to be
identified and reported:
- Cooling
equipment and operation using normal user
controls.
- Cooling
distribution system(s) including a
representative sampling of ducting, duct
insulation, outlets, piping systems and valves.
- Energy source
and connections.
- Condensate
drains.
B. The inspector is
not required to:
- Determine
uniformity, temperature, airflow or balance of
cool air supply to any room or building, or
examine for cooling at any cooling system
distribution component when access would require
steps or a ladder, or determine leakage in any
ductwork.
- Examine
electrical current, coolant fluids or gases, or
coolant leakage.
- Examine
electronic filtering systems.
- Determine or
examine thermostat calibration, cooling
anticipation, or automatic setbacks or clocks.
- Examine any
non-central cooling unit(s) or gas-fired, solar
or geothermal cooling system or food, wine or
similar storage cooling system.
- Examine
humidity control systems and components.
SECTION 9 - Fireplaces
and Chimneys
Top
A. Items to be
identified and reported:
- Chimneys,
flues, dampers and associated components.
- Fireboxes,
hearth extensions and permanently installed
accessory components.
- Manufactured
solid-fuel or gas-burning appliances.
B. The inspector is
not required to:
- Determine
adequacy of draft, perform a smoke test, or
dismantle or remove any component.
- Examine the
structural integrity of fireplaces and chimneys.
- Examine or
operate ancillary or non-permanently installed
components.
SECTION 10 - Building
Interior
Top
A. Items to be
identified and reported:
- Walls,
ceilings and floors.
- Security bars,
ventilation components, and a representative
sampling of doors and windows.
- Stairs,
handrails, and guardrails.
- Permanently
installed cabinet and countertop surfaces.
- Safety glazing
in locations subject to human impact.
B The inspector is
not required to:
- Operate or
evaluate security bar release and opening
mechanisms, whether interior or exterior,
including compliance with local, state, or
federal standards.
- Determine
whether a building is secure from forcible or
unauthorized entry.
- Evaluate the
condition of floor, wall or ceiling finishes or
coverings, or other surfaces for other than
evidence of moisture damage.
- Examine window
or door coverings or treatments.
- Evaluate
fastening of countertops, furniture or cabinets
supported by floors, ceilings and/or walls.
- Evaluate
separation walls, ceilings, and floors,
including, but not limited to, the fire-
resistivity or acoustical characteristics,
between dwelling units.
- Examine the
interior concrete slab-on-grade when concealed
by any floor coverings.
- Operate or
evaluate safety features of any garage door
opener unless included as an inspection option
per Section 11.
SECTION 11 (OPTIONAL) -
Other Built-In Appliances and Systems
Top
The inspector may
examine any of the following at his/her discretion, as
agreed with client:
Attic power vents, central vacuum, cook-tops and exhaust
fans, dishwashers, food waste disposers, garage door
openers, hydrotherapy tubs, ovens, microwave ovens,
refrigerators, freezers, trash compactors, or
whole-house fans.
A. Items to be
identified and reported:
- Optional
systems, components and appliances specifically
examined during the inspection.
- Basic
operation of optional systems, components and
appliances specifically included in the
inspection.
B. The inspector is
not required to:
- Activate any
system or appliance that is shut down.
- Operate or
evaluate any system, component, or appliance
that does not respond to normal user controls.
- Operate any
gas appliance that requires the use of a match
or other remote burner lighting device.
- Operate any
system or appliance that requires the use of
special codes, keys, combinations, or devices.
- Operate any
system, component, or appliance where damage may
occur.
- Determine
thermostat(s) calibration, adequacy of heating
elements, operate or evaluate self-cleaning oven
cycles, signal lights, or automatic setbacks or
clocks.
- Determine
leakage from microwave ovens.
- Determine the
presence or operation of backdraft damper
devices in exhaust devices.
- Examine any
sauna, steam-jenny, kiln, clothes washing or
drying machine, toaster, ice-maker,
coffee-maker, can-opener, bread-warmer, blender,
instant hot water dispenser, or any other
similar small, ancillary or non-built-in
appliances.
SECTION 12 (OPTIONAL) -
Pools and Spas
Top
The inspector may
examine the following at his/her discretion, as
agreed with client:
A. Items to be identified and reported:
- 1. Location
and type of pool or spa examined.
- Conditions
limiting or otherwise inhibiting inspection.
- Enclosure and
related gates.
- Hardscaping
and drainage related to the inspected pool or
spa.
- Condition of
visible portions of systems, structures, or
components.
- Normally
necessary and present equipment such as: lights,
pumps, heaters, filters, and related mechanical
and electrical connections.
B. The inspector is
not required to:
- Examine any
above-ground, movable, freestanding or otherwise
non-permanently installed pool or spa, or
self-contained equipment.
- Come into
contact with pool or spa water to examine the
system, structure, or components.
- Determine
adequacy of spa jet water force or bubble
effect.
- Determine
structural integrity or leakage of any kind.
- Evaluate
thermostat(s) or their calibration, heating
elements, chemical dispensers, water chemistry
or conditioning devices, low voltage or computer
controls, timers, sweeps or cleaners, pool or
spa covers and related components.
- Operate or
evaluate filter backwash systems.
- Examine
accessories, such as, but not limited to:
aerators or air-blowers, diving or jump boards,
ladders, skimmers, slides or steps.
III. LIMITATIONS,
EXCEPTIONS AND EXCLUSIONS
Top
*Note: All limitations, exceptions and exclusions apply
equally to mandatory and optional Sections.
A. The inspector
may exclude from the inspection any system,
structure, or component of the building which is
inaccessible, concealed from view, or cannot be
inspected due to circumstances beyond the control of
the inspector, or which the client has agreed is not
to be inspected. If an inspector excludes any
specific system, structure, or component of the
building from the inspection, the inspector shall
confirm in the report such specific system,
structure, or component of the building not
inspected and the reason(s) for such exclusion(s).
B. The inspector may limit the inspection to
individual specific systems, structures, or
components of the building. In such event, the
inspector shall confirm in the report that the
inspection has been limited to such individual
specific systems, structures, and components of the
building.
C. The following are excluded from the scope of a
real estate inspection unless specifically agreed
otherwise between the inspector and the client:
- Systems,
structures, or components not specifically
identified in these Standards.
- Environmental hazards or conditions, including,
but not limited to, toxic, reactive, combustible,
corrosive contaminants, wildfire, geologic or flood.
- Examination of conditions related to animals,
rodents, insects, wood-destroying insects,
organisms, mold, and mildew.
- Geotechnical, engineering, structural,
architectural, geological, hydrological, land
surveying or soils-related examinations.
- Certain factors relating to any systems,
structures, or components of the building,
including, but not limited to: adequacy, efficiency,
durability or remaining useful life, costs to
repair, replace or operate, fair market value,
marketability, quality, or advisability of purchase.
- Systems, structures, or components, of the
building which are not permanently installed.
- Determination of compliance with installation
guidelines, manufacturers’ specifications, building
codes, ordinances, regulations, covenants, or other
restrictions, including local interpretations
thereof.
- Common areas, or systems, structures, or
components thereof, including, but not limited to,
those of a common interest development as defined in
California Civil Code Section 1351 et seq.
D. The inspector is
not required to perform any of the following as part
of a real estate inspection:
- Move any personal items or other obstruction(s)
such as, but not limited to: furniture, floor or
wall coverings, window coverings, snow, ice, water,
debris, and foliage which may obstruct visibility or
access.
- Determine causes for the need of repair or
replacement, or specify repair or replacement
procedures or materials.
- Determine existence of latent deficiencies or
defects.
- Dismantle any system, structure, or component, or
perform any intrusive or destructive examination,
test or analysis.
- Obtain or review information from any
third-parties including, but not limited to:
government agencies (such as permits), component or
system manufacturers (including product defects,
recalls or similar notices), contractors, managers,
sellers, occupants, neighbors, consultants,
homeowner or similar associations, attorneys, agents
or brokers.
- Activate or operate any system or component that
is shut down or does not respond to normal user
controls, nor access any area or operate any
component or system which may jeopardize the safety
of the inspector, or any other person or thing.
- Research the history of a property, report on its
potential for alteration, modification,
extendibility, or its suitability for a specific or
proposed use or occupancy.
- Offer any form of guarantee or warranty.
- Examine or evaluate the acoustical or other
nuisance characteristics of any system, structure,
or component of a building, complex, adjoining
properties, or neighborhood.
- Operate or evaluate any recreational system,
structure or component.
- Operate or evaluate low voltage electrical (less
than single-phase line voltage, typically
120-volts), antennas, security systems, cable or
satellite television, telephone, remote controls,
radio controls, timers, intercoms, computers,
photo-electric, motion sensing, or other such
similar non-primary electrical power devices,
components, or systems.
- Use any special equipment to examine any system,
structure, or component of a building.
- Probe or exert pressure on any component, system
or structure.
- Examine or evaluate fire-resistive qualities of
any system, structure or component of the building.
- Examine every individual component of a system
or structure, where such components are typically
replicated, including, but not limited to: doors,
windows, switches and receptacles. A representative
sampling may be performed in order to examine such
systems, structures, or components of a building.
- Determine the age of construction or
installation of any system, structure, or component
of a building, or differentiate between original
construction or subsequent additions, improvements,
renovations or replacements thereto.
|